Test ograniczenia strat wynikłych z nadmiernego nagrzewania zbiornika kriogenicznego zawierającego ciekły tlen.
Firma Linde Gas Singapore
|
 |
Test
- Linde Gas (Singapore) Pte Ltd
- 5-letni zbiornik zawierający ciekły tlen
Wymiary
|
|
|
Poziom
|
Ciśnienie kPa
|
|
Data
|
Rano
|
Wieczorem
|
Rano
|
Wieczorem
|
|
3/Jul/03
|
2350
|
5750
|
1350
|
950
|
|
4/Jul/03
|
5730
|

|
1000
|
1
|
|
7/Jul/03
|
5700
|
5700
|
1100
|
1120
|
|
8/Jul/03
|
5690
|
5690
|
1150
|
1180
|
|
9/Jul/03
|
5690
|
5690
|
1200
|
1200
|
|
10/Jul/03
|
5670
|
5670
|
1220
|
1250
|
|
11/Jul/03
|
5670
|
5565
|
1260
|
1290
|
|
14/Jul/03
|
5620
|
5560
|
1350
|
1350
|
|
15/Jul/03
|
5610
|
5610
|
1360
|
1350
|
|
16/Jul/03
|
5610
|
5600
|
1370
|
1340
|
|
17/Jul/03
|
5600
|
5600
|
1370
|
1340
|
|
18/Jul/03
|
5600
|
5600
|
1380
|
1340
|
|
19/Jul/03
|
5600
|
5600
|
1340
|
1340
|
|
21/Jul/03
|
5600
|
5600
|
1370
|
1340
|
|
22/Jul/03
|
5550
|
1
|
1370
|
1
|
|
23/Jul/03
|
5520
|
5320
|
1390
|
1390
|
|
24/Jul/03
|
5338
|
5320
|
1390
|
1350
|
|
25/Jul/03
|

|

|

|
1
|
|
26/Jul/03
|

|

|

|

|
|
27/Jul/03
|

|

|

|

|
|
28/Jul/03
|
4990
|
4990
|
1110
|
1110
|
|
29/Jul/03
|
4980
|

|
1180
|

|
|
30/Jul/03
|

|

|

|

|
|
31/Jul/03
|
4950
|

|
1220
|

|
|
1/Aug/03
|
4940
|

|
1300
|

|
|
2/Aug/03
|
4910
|

|
1310
|

|
|
3/Aug/03
|

|

|

|

|
|
4/Aug/03
|
4900
|
4900
|
1380
|
1380
|
|
5/Aug/03
|
4900
|
4895
|
1380
|
1380
|
Przed wykonaniem izolacji z użyciem INSULADD® ciśnienie w zbiorniku wynosiło 1500 kPa.
Wykonanie izolacji kosztowało 1000 usd i zwróciło się w ciągu 4 miesięcy w wyniku ograniczenia parowania gazu.
Szacowany zysk roczny wynikający z izolacji to 3000 usd.
|